Everything a person can do on Ohmforge Wire Gauge, Voltage Drop & Harness Calculator, a program or AI agent can do with the same inputs and get the identical result.

HTTP API

Ohmforge Wire Gauge, Voltage Drop & Harness Calculator

Pick the conductor for a DC, single-phase or three-phase run from the current, the cable length and the voltage drop you allow, with copper or aluminium at the conductor temperature — results in AWG and in metric mm², with drop, power loss and a fuse suggestion as guidance. Convert between AWG and mm² with the ASTM B258 formula, or turn a harness wire list into a cut list with allowances, a bill of materials per gauge and colour, CSV exports and a continuity check against an Ohmforge schematic.

Inputs of Ohmforge Wire Gauge, Voltage Drop & Harness Calculator
FieldTypeDefaultDescription
modeselect (size, table, harness)"size"Task
voltagenumber12Supply voltage. Three-phase: line-to-line voltage.
currentnumber20Load current
lengthMnumber5Cable length (one way). Distance from the source to the load; the return conductor is added automatically.
circuitselect (dc, chassis, three-phase)"dc"Circuit
maxDropPercentnumber3Allowed voltage drop
temperatureCnumber20Conductor temperature. Resistance rises about 0.4 % per °C; use the operating temperature for a conservative result.
materialselect (copper, aluminium)"copper"Conductor
fuseSeriesselect (blade, iec)"blade"Fuse ratings
converttext"2.5 mm²"Size to convert (table). For example 12 AWG, 4/0, 2.5 mm² or 0.75mm2.
wirestextarea"# id, from, to, length (m), gauge, colour\nW1, BT1.+, F1.1, 0.30, 4 mm², RD\nW2Wire list (harness). One wire per line: id, from, to, length, gauge, colour (comma, semicolon or tab). Ends as REF.PIN (BT1.+, F1.1) to check them against a schematic; ends without a dot are splices or studs.
lengthUnitselect (m, mm)"m"Length unit of the wire list
bareGaugeselect (awg, metric)"awg"A bare whole number in the gauge column means
allowancePerEndMmnumber20Strip and termination allowance per end
slackPercentnumber5Slack and service loops
projecttextarea—Ohmforge project for the continuity check (optional). Paste a .ohmforge.json project; the harness is checked against its nets.

Example request

12 V, 20 A over 5 m (van or boat)

curl -X POST https://ohmforgewiregauge.usefulweb.site/api/v1/calculate -H 'content-type: application/json' -d '{"mode":"size","voltage":12,"current":20,"lengthM":5,"circuit":"dc","maxDropPercent":3,"temperatureC":20,"material":"copper","fuseSeries":"blade"}'

Every result contains

inputs (normalised, defaults applied), summary, result (validated against the published schema), units, assumptions, sources, warnings, computedAt and links.